<LOGO>
FM Transmitter Measurement Report
Created: 2026-09-20 12-16-29
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 51 dBuV SANDELS
Pilot RDS Phase Difference
4.9 kHz 5.7 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
12 kHz 66 kHz 16827 12,5631
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,7 dBr 4,40 dBr 5,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7, 103.8 MHz -
FM Scope Max at: 66 kHz MIN: 12 kHz % above 76 kHz: 12,5631 Acquired: 2026.09.20 12.15.26 Total samples: 16827 Equivalent time: 0:14:01 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 5,9 dBr MIN: 2,7 dBr AVE: 4,40 dBr % above 12,2 dBr: 0,0 Last value: 4,1 dBr (2026.09.20 12.15.26) 12.02 12.04 12.06 12.08 12.10 12.12 12.14 0 2 4 6 Pm [dBr]